Healthcare Communications for today... and tomorrow.
Tek-CARE® NC110, NC150, NC200 Nurse Call Systems

NC200N
Master Station Panel
(desk mount only)
Tek-CARE® NC110, NC150 & NC200 are UL® listed audio-visual nurse call systems for nursing home, hospital, and health care related facilities.
They provide audible and visual call indication without the use of intercom communications. Annunciator/control panels are modular and available in different lamp indicator quantities from 4 to more than 100. Add door and window monitoring to the nurse call system by using our DS100 door sentry & emergency alarm system.

NC150/12 Annunciator
with OF202 Frame &
optional TA150N Handset

NC110/32 Annunciator
with OF201 Frame,
NC110A LED Annunciator
Take a look at our other healthcare communications systems:
Tek-CARE® NC300™II |
Tek-CARE®400 |
Tek-CARE®500 |
Tek-MMARS®II |
Tek-PAGING®
More Information on
Tek-CARE®NC110, NC110A, NC150, NC200
Condensed Catalog Section E - IL691
NC110 & NC110A Spec Sheets
NC150/NC200 Spec Sheets
Block Wiring Diagrams
Installation Manuals
Sales Bulletins
TekTips
Architects' & Engineers' Specs
Fillable button label strips for NC110A Master Stations (WORD Format)
Spec Sheets—NC110, NC110A UL® Listed
Audible-Visual nurse call system
(PDF Format; Click on
to view a product photo)
- Tek-CARE® NC110, NC110A Submittal Package (all spec sheets)
- NC110N - Master station - IL365

- NC110A - 50-point LED master station - IL850

- Frame and Housing Chart - IL312
- IH300 - series desk housing for NC110 master panels - IL502
- IH151N - Junction box - IL646
- PK151A - Annunciator power and control unit (routine, emergency) - IL367
- SS106 Transformer - IL127
- PK153 - Third priority (code blue) control unit - IL473
- PK800A - Auxiliary power supply - IL664
- SF100C - Single patient station - 1/4" jack - IL362

- SF101C - Push button call station - IL366

- SF102 - Dual patient station - 1/4" jacks - IL639

- SF301A/SF302 - Single and dual pushbutton call cords - 1/4" jack - IL338

- SF301G/SF302G - Single and dual geriatric call cords (oxygen environment) - IL434

- SF155B - Emergency call station - IL513

- SF156B - Code blue call station - IL648

- SF339 - Emergency station with mushroom-style pushbutton - IL744

- LI381/LI382 - Single- and dual-bulb corridor dome lamps - IL518

- LI150B - Duty station - IL654
- PK124K Kit - Combined Spec Sheets for battery backup kit
Spec Sheets—NC150, NC200 UL®Listed
Audio-Visual nurse call systems
(PDF Format; Click on
to view a product photo)
- Tek-CARE® NC150, NC200 Submittal Package (all spec sheets)
- NC150N - Master station - IL363

- NC200N - Master station - IL364

- Frame and Housing Chart - IL312
- IH300 - series desk housing for NC150N master panels - IL502
- IH200 - series desk housing for NC200N master panels - IL501
- IH151N - Junction box - IL646
- PK151A - Annunciator power and control unit (routine, emergency) - IL367
- SS106 Transformer - IL127
- PM151/4 - 4-station door answering module - IL305
- OR603W - Outdoor station, white plastic, for use with PM151/4 - IL538

- OR501B - Outdoor station, aluminum, for use with PM151/4 - IL438

- PK153 - Third priority (code blue) control unit - IL473
- PK800A - Auxiliary power supply - IL664
- IR150B - Staff station - IL726

- IR151B/IR152B - Single and dual patient stations - 1/4" jack - IL727
/

- IR155B - Pull cord single patient station - IL728

- SF301A/SF302 - Single and dual pushbutton call cords - 1/4" jack - IL338

- SF301G/SF302G - Single and dual geriatric call cords (oxygen environment) - IL434

- SF155B - Emergency call station - IL513

- SF156B - Code blue call station - IL648

- SF339 - Emergency station with mushroom-style pushbutton - IL744

- LI381/LI382 Single- and dual-bulb corridor dome lamps - IL518

- LI150B - Duty station - IL654
- PK124K Kit - Combined Spec Sheets for battery backup kit
Block Wiring Diagrams
(PDF Format)
- Tek-CARE® NC150, NC200 - Block Wiring Diagrams - From IL380
Installation Manuals
(Password required. Call US & Canada Sales to obtain one.)
NC110, NC110A
- Tek-CARE® NC110, NC110A - Installation and Instruction Manual - IL381
- PK124 - Battery charger wiring diagram - IL426
NC150, NC200
- Tek-CARE® NC150, NC200 - Installation and Instruction Manual - IL380
- Tek-CARE® NC150, NC200 - with PM151/4 door intercom module - IL392
- TA150N, TA200N - Handset - IL738
- PK124 - Battery charger wiring diagram - IL426
Sales Bulletins
- SSB 16 - Wireless pendant / Transmitter use with NC110 and NC150
- SSB 6 - NC375 Programming Software & Telephone Entry plug added
- SSB 5 - NC375 Radio Paging Voltage Room Number Instructions
TekTips
- NC267 Wiring Information and Pointers
- Interchanging old model NC150U with new NC150/NC200 Nurse Call Systems
- Wiring connections necessary to control TV with the IR157N Patient Station and SF301P Pillow Speaker combination
- "Phantom Calls" Troubleshooting
- Wiring NC150/NC200
- Tone Loss NC150/NC200 Troubleshooting
- Testing the PK151N
- SF100C/SF101C Wiring Application: Cross reference wiring diagrams for NC110 application
- Two-Station Application NC150/NC200
- Two New Application Drawings for NC267 Wireless Receivers
- 3M™ Scotchlok™ Connectors
Architects' & Engineers' Specs
(WORD Format)
- NC110 with third priority option
- NC110 with emergency stations used in bed, living and bath locations
- NC150 Audio Visual system
To open a file in MS Word, left-click on its link. To save a file on your computer to open later, right-click on its link and choose "Save Target As" (in Internet Explorer) or "Save Link As" (in Netscape). If you need the files in another format, call our sales department, or download an MS Word viewer from microsoft.com. Just search their downloadable products database for a viewer that meets your needs.
TekTone® Sound & Signal Mfg., Inc.
277 Industrial Park Road
Franklin, NC 28734
USA
Phone: (828) 524-9967
Fax: (828) 524-9968
Sales: (800) 327-8466
Tech Support: (800) 332-6608